24 CFR §200.926a — Residential building code comparison items
24 CFR §200.926a, Residential building code comparison items. An FHA program rule in Subpart S—Minimum Property Standards of 24 CFR Part 200 (Introduction to FHA Programs).
Verbatim regulatory text
Verbatim provisions from 24 CFR §200.926a — Residential building code comparison items — each quote is a verified substring of the regulator-published source snapshot, not retyped. Quoted for reference; this is not legal advice. The operational layer (P&P updates, prompts) lives in the regulation update kits.
24 CFR §200.926a(a)
HUD will review each local and State code submitted under this subpart to determine whether it regulates all of the following areas and subareas: (a) Fire Safety. (1) Allowable height; (2) Fire separations; (3) Fire resistance requirements; (4) Egress doors and windows; (5) Unit smoke detectors; (6) Flame spread.
24 CFR §200.926a(b)
(b) Light and ventilation. (1) Habitable rooms; (2) Bath and toilet rooms.
24 CFR §200.926a(c)
(c) Structural loads and seismic design. (1) Design live loads; (2) Design dead loads; (3) Snow loads (for jurisdictions with snow loading conditions identified in Section 7 of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in seismic zones 3 or 4, as identified in Section 9 of ASCE-7-88 (formerly ANSI A58.1-82)).
24 CFR §200.926a(d)
(d) Foundation systems. (1) Foundation depths; (2) Footings; (3) Foundation materials criteria.
24 CFR §200.926a(e)
(e) Materials standards. (1) Materials standards.
24 CFR §200.926a(f)
(f) Construction components. (1) Steel; (2) Masonry; (3) Concrete; (4) Lumber; (5) Roof construction and covering; (6) Chimneys and fireplaces.
24 CFR §200.926a(g)
(g) Glass. (1) Thickness/area requirements; (2) Safety glazing.
24 CFR §200.926a(h)
(h) Mechanical. (1) Heating, cooling and ventilation systems; (2) Gas, liquid and solid fuel piping and equipment; (3) Chimneys and vents; (4) Ventilation (air changes).
24 CFR §200.926a(i)
(i) Plumbing. (1) Materials standards; (2) Sizing and installing drainage systems; (3) Vents and venting; (4) Traps; (5) Cleanouts; (6) Plumbing fixtures; (7) Water supply and distribution; (8) Sewage disposal systems.
24 CFR §200.926a(j)
(j) Electrical. (1) Branch circuits; (2) Services; (3) Grounding; (4) Wiring methods; (5) Cable; (6) Conduit; (7) Outlets, switches and junction boxes; (8) Panelboards.
Get this regulation in your AI window
Put the verbatim text and its effective date in front of your assistant, instead of whatever it remembers.
Add to Claude shows the one-time setup: paste one address, no account with us. Add to ChatGPT adds the free C4C app from ChatGPT’s app directory. Either way it’s free.
Get notified if this rule changes
One email when 24 CFR §200.926a — Residential building code comparison items changes: what changed, the new verbatim text, and the effective date. Nothing else.
Double opt-in: we send a confirmation link first. Following one section does not subscribe you to anything else. Privacy.
Source of record: https://claudeforcompliance.com/regs/fha-24cfr-200-926a/
· register fha-24cfr-200-926a · verbatim, source-snapshotted regulator text from the
Claude for Compliance corpus. To work from every register at once, download the corpus
and follow the methodology.